BXHGB - LIQUID PAPER MULTI FLUID CORRECTION FLUID (LPCF-15)

Product Identification

Product ID:LIQUID PAPER MULTI FLUID CORRECTION FLUID (LPCF-15)
MSDS Date:12/12/1991
FSC:7510
NIIN:01-396-1184
MSDS Number: BXHGB

Responsible Party
GILLETTE MEDICAL EVALUATION LABORATORIES
401 PROFESSIONAL DR
GAITHERSBURG, MD 20879
US

Emergency Phone: 301-590-9781

Info Phone: 301-590-9781

Cage: 9A977

Contractor
GILLETTE MEDICAL EVALUATION LABORATORIES
196 ROCKVILLE, MD 20850 US

Telephone: 301-424-2000

Cage: 9A977

Ingredients

212F,100C.

CAS: 108-87-2

RTECS: GV6125000

OSHA PEL 500 PPM

ACGIH TLV: 400 PPM


>1 (BUTYL ACETATE=1). SOL IN

RTECS: 9999999ZZ

OSHA PEL N/K

ACGIH TLV: N/K


TITANIUM OXIDE; (TITANIUM DIOXIDE)

CAS: 13463-67-7

RTECS: XR2275000

OSHA PEL 15 MG/M3 TDUST

ACGIH TLV: 10 MG/M3 TDUST


RESINS, DISPERSANTS, COLORANTS

OSHA PEL N/K

ACGIH TLV: N/K


ISOTHIOCYANIC ACID, ALLYL ESTER; (MUSTARD OIL)

CAS: 57-06-7

RTECS: NX8225000

OSHA PEL N/K

ACGIH TLV: N/K


FRAGRANCE; (MASKING FRAGRANCE)

OSHA PEL N/K

ACGIH TLV: N/K

Hazards

LD50 LC50 Mixture:LD50:(ORAL,RAT) >5 ML/KG.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHAL:NO ADVERSE EFTS ANTIC FROM
NORMAL USE. IF VAPS ARE DELIB CONC & INHALED (ABUSE), FOLLOWING
SYMPS MAY OCCUR:RESP IRRIT, DIZZ, DROW, HDCH, NAUS, UNCON, CONVLS,
CARDIAC SENSIT, COMA & DEATH. (MUSTA RD OIL IS ADDED TO PROD AS
ABUSE DETERRENT). INGEST:NO ADVERSE EFTS ANTIC FROM NORMAL USE.
DEPENDING ON(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:AMT INGESTED, MOST OF SYMPS DESCRIBED
ABOVE MAY OCCUR. ASPIR MAY RSLT IN CHEM PNEUM. SKIN CONT:NO ADVERSE
EFTS FROM NORMAL USE. IRRIT MAY OCCUR IF CONT IS PRLNG/RPTD. SKIN
ABSORPTION:NO ADVER SE EFTS ANTIC FROM NORMAL USE. SOLV CANBE
ABSORBED THRU SKIN (PRLNG CONT), BUT NOT LIKELY IN ACUTELY TOX
AMTS. (SUPDAT)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:EYES:FLUSH W/PLENTY OF WATER FOR AT LST 15 MINS. IF IRRIT
PERSISTS, OBTAIN MED ATTN. SKIN:WASH W/SOAP & WATER. INHAL:TREAT
SYMPTOMATICALLY. OXYGEN MAY BE ADMINISTERED. SEEK MED ATTN IMMED &
REFER TO N OTES TO MD. INGEST:CONSULT MD. NOTES TOMD:CONTAINS ING 1
WHICH, IF ASPIR, MAY CAUSE CHEM PNEUM. INHAL OF CONC VAPS MAY PRDCE
CARDIAC SENSIT, CONTRAINDICATING USE OF SYMPATHOMIMETIC AGENTS.

Fire Fighting

Flash Point Method:CC
Flash Point:22.0F,-5.6C
Lower Limits:1.2%
Upper Limits:6.7%
Extinguishing Media:DRY CHEMICAL, FOAM, CARBON DIOXIDE.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT . COOL FIRE-EXPOSED CONTAINERS W/WATER FOG/SPRAY.
Unusual Fire/Explosion Hazard:PRODUCT IS FLAMMABLE. MAY PRODUCE
HAZARDOUS DECOMPOSITION PRODUCTS.

Accidental Release

Spill Release Procedures:PICK UP SPILLS W/TOWELS, TISSUES, ETC.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:PRODUCT IS FLAMMABLE.
Other Precautions:NO UNUSUAL HANDLING OR STORAGE WHEN USED AS DIRECTED;
WHEN STORED IN LARGE QUANTITIES (AS IN WAREHOUSE), IT SHOULD BE IN
A WELL-VENTILATED, COOL AREA, AWAY FROM IGNITION SOURCES.

Exposure Controls

Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN . NONE UNDER NORMAL USE CONDITIONS.
Ventilation:NONE UNDER NORMAL USE CNDTNS. PROD IS NON-HAZ WHEN USED AS
DIRECTED IN AN OFFICE/ROOM W/NORMAL AIR CIRCULATION.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
ANSI DESIGN CRITERIA .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
EFTS OF OVEREXP:EYE CONT:IRRITATION CAN OCCUR.

Chemical Properties

Boiling Pt:B.P. Text:SEE ING 1
Vapor Pres:SEE ING 1
Vapor Density:SEE ING 1
Spec Gravity:1.2 (H*2O=1)
Evaporation Rate & Reference:SEE INGREDIENT 1.
Solubility in Water:SEE INGREDIENT 1.
Appearance and Odor:WHITE FLUID W/PUNGENT SOLVENT ODOR.
Percent Volatiles by Volume:50

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS.
Stability Condition to Avoid:PRODUCT IS FLAMMABLE. AVOID CONTACT W/OPEN
FLAME OR OTHER IGNITION SOURCES.
Hazardous Decomposition Products:THERMAL DEGRADATION MAY PRODUCE OXIDES
OF CARBON & NITROGEN & VARIOUS HYDROCARBONS.

Disposal

Waste Disposal Methods:DISPOSE I/A/W APPLICABLE FEDERAL, STATE & LOCAL
LAWS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.